Electrical system
8
Fuse on the solar charge
regulator (special
equipment)
The fuse is located on the solar charge regulator.
Changing:
Disconnect all 12 V appliances.
Replace fuse (Fig. 130,1).
8.10.2 230 V fuse
A fault current protection switch (FI-switch) (Fig. 131,4) in the fuse box
(Fig. 131,3) protects the complete vehicle from fault current (0.03 A).
The downstream safety cut-out (10 A) (Fig. 131,2) secures the 230 V sockets,
the power supply unit, the auxiliary charging unit and the refrigerator.
For vehicles with special equipment, e.g. air conditioning unit, an additional
safety cut-out (16 A) (Fig. 131,1) secures the device.
Position See chapter 16.
Checking fault current
protection switch:
When the vehicle is connected to the 230 V power supply, press the test
button (Fig. 131,5). The fault current protection switch (RCD) must be acti-
vated.
Fig. 130 Solar charge regulator fuse
1 Flat fuse 5 A/light brown
Z Check the fault current protection switch for each connection to the 230 V
power supply, at least once every 6 months.
Fig. 131 230 V fuse box with safety cut-
out and FI-switch