Troubleshooting
14
14.6.2 Telair
14.7 Cooker
14.7.1 Gas cooker/gas oven
Water is entering the ve-
hicle
Drainage holes for con-
densation are clogged
Clean air conditioning
unit
Seal is defective Contact customer service
No more air circulation Air filter clogged Clean air filter
Fan wheel defective Contact customer service
Fault Cause Remedy
Air conditioning unit does
not start up
No 230 V power supply Connect 230 V power
supply
230 V automatic circuit
breaker has triggered
Switch on the 230 V au-
tomatic circuit breaker
Remote control batteries
empty
Change batteries
(2 x AAA)
Air conditioning unit does
not cool
Room temperature is
lower than the preset
temperature
Reset temperature
Air conditioning unit does
not heat
Room temperature is
higher than the preset
temperature
Reset temperature
Insufficient ventilation rat-
ing
Ventilation flaps closed Open at least one venti-
lation flap
Filter dirty Clean the filter
Water is entering the ve-
hicle
Drainage holes for con-
densation are clogged
Clean air conditioning
unit
Fault Cause Remedy
Ignition fuse does not op-
erate (flame does not
burn after the control
knobs are released)
Heat-up time is too short Keep control knob
pressed for approx. 15 to
20 seconds after ignition
Ignition fuse is defective Contact customer service
Flame extinguishes when
being reduced to its mini-
mum setting
Thermocouple sensor is
incorrectly set
Correctly reset thermo-
couple sensor (do not
bend). The sensor tip
should protrude by 5 mm
beyond the burner. The
sensor neck should not
be more than 3 mm away
from the burner ring; if
necessary, contact cus-
tomer service
Fault Cause Remedy